Chemical anchor Teknobond 400P

Directory > Adhesives and sealants

Chemical anchor Teknobond 400P

Water-resistant two-component, thixotropic, quick-drying hibanker.

258
uah
x
упак.
=
258 uah
Wholesale price 219.3 uah from 10 упак.

For you, there will be a greater sense of the price of the proposition. Be affectionate, send a request and managers create an individual prorachunok for you.

CHECKOUT

Enter your name and phone number

Water-resistant two-component, thixotropic, quick-drying chemical composition based on synthetic epoxy acrylate resin.

Applications:

  • Mounting and replacement of valves in the construction of bridges, ceilings, stairs, pillars, ramps, etc
  • Bonding issues of the working armature at the building Foundation, compound walls, floor slabs
  • Fixing of steel elements
  • Housing construction (roof, balconies, gates, arbors, etc.)
  • Installation of auxiliary equipment (satellite dishes, plumbing, lights, railings, balustrades, etc.)
  • Installation of equipment that requires electrical insulation, for example, installing handrails in the tunnels


The features and benefits

  • Can be used for wet holes
  • Not only suitable for threaded components fasteners, but also fittings
  • Resistance to vibration
  • High bearing capacity and tensile strength.
  • Has a high resistance to chemicals
  • The monolithic connection that is as durable base material
  • Ideal for porous and hollow materials
  • The tightness and durability of the connection
  • Easy to apply even on wet surfaces

Instructions for application:

Surface for application should be cleaned from dust, dirt, loose particles, residues of cement, oils and fats. The concrete substrate must be clean, durable and have adequate compressive strength.

Surface for application should be cleaned by applying compressed air to maintain maximum adhesion.

Temperature of surface and environment should be min 5 ° C. 35 ° C max.

In order to open the cover, turn it. Then, install static mixer. Place the cartridge into the gun and start application. When you stop the coating process, the tip of the static mixer can be left on the cartridge after the pressure in the atomizer is released. If in a static mixer resin is hardened, before you start, you need to install a new insert. When you store an open cartridge, remove the static mixer, turn it, wipe the neck of the cartridge with a clean dry cloth and close the cover.

Application method: Drill a hole of required diameter and depth using the drill. The diameter and depth of the hole should match the size used anchor element. The hole should be cleaned from the inside round wire brush and compressed air. Then hold the trigger until the two separate components of the cartridge will not come out of the static mixer. Slowly pull the cartridge, filling the hole with resin starting from the bottom of the hole. Make sure that inside there are no air gaps.

In deep holes, you can use an extension cord. Rotate the anchor when you insert it. If a certain amount of resin came out, the anchor element should be placed at the hole during the period of gelation of the resin. During hardening, in any case can not move or load the anchor element. During application should be used work clothes, protective glasses and gloves. Material components must not be in contact with skin and eyes, in case of contact, immediately wash with plenty of soap and water.

Packaging

345 ml cartridge

Storage conditions

12 months in unopened original packaging

The life time of the mixture

~ 7-10 minutes (20°C)

Complete drying

7 days

Time re-application

1 hour 20°C

Thermostability

0 °C to 80 °C

Pressure strength

60-70 N / mm2

The force of adhesion (to concrete)

≥4 N/mm2

Flexural strength

18-20 N/ mm2

Strength on the tension

≤ 0.6 mm (under a 75 kN load)

Standard

In accordance with TS EN 1504-6